Show simple item record

dc.contributor.authorPlaisted, Joshua R.en_US
dc.date.accessioned2007-05-14T14:40:43Z
dc.date.available2007-05-14T14:40:43Z
dc.date.issued2000en_US
dc.identifier.citationPlaisted, J.R. (2000). Life Cycle Performance Evaluation of an Air-Based Solar Thermal System. Master's Thesis, University of Wisconsin-Madison.en_US
dc.identifier.urihttp://digital.library.wisc.edu/1793/7652
dc.descriptionUnder the supervision of Professors William Beckman and John Mitchell; 226pp.en_US
dc.description.abstractPerformance at the McKay center after 22 years of operation was characterized through experimental measurements of component parameters. Effects of the component parameters on systems level performance was evaluated using numerical simulation tools (TRNSYS) calibrated against actual operation of the building. Calibration of the collector arrays indicated degradations of 16 percent in Fr(??) and 19 percent in FrUL on average for the two arrays installed at the site. Thermal losses from the pebble beds were characterized by conductances of 7.5 and 3.0 W/m2-C for the two beds, which far exceed the design conductance of 0.65 W/m2-C. Flow distributions within the beds were highly non-uniform with an average 3:1 flow ratio across the pebble beds. Effects of component degradations did not directly translate into similar systems level degradations. Annual simulations performed under typical meteorological year (TMY2) conditions indicated that the high bed losses and non-uniform flow have resulted in a 1 percentage point decrease in the solar fraction. Degradations in the collector array had a more significant effect on system performance, lowering the solar fraction by 12 percentage points. Together, physical deteriorations of the solar components have lowed the solar fraction from an optimum of 45 percent to 32 percent. The single largest effect on system performance was not attributable to a physical component, but to the control logic that governs system operation. Faulty operation of an air damper within the system and improper location of a control sensor were responsible for the low solar fraction of 15 percent representative of how the system was found at the inception of this study. In-situ testing methods and novel calibration techniques are described that result in minimal cost and interference of system operation. Systems level calibrations employing daily integrated energy comparisons are also discussed along with the sensitivity of the model to load dynamics. Possible methods of fault detection for solar thermals systems and a minimal instrumentation package are presented that may prevent similar faults from compromising the performance of present and future solar installations.en_US
dc.description.sponsorshipFunded by the Heckrodt Foundation.en_US
dc.format.extent2081898 bytes
dc.format.mimetypeapplication/pdfen_US
dc.format.mimetypeapplication/pdf
dc.publisherUniversity of Wisconsin-Madisonen_US
dc.subjectThesis (M.S.)--University of Wisconsin--Madison, 2000.en_US
dc.subjectDissertations Academic Mechanical Engineering.en_US
dc.subjectUniversity of Wisconsin--Madison. College of Engineering.en_US
dc.titleLife Cycle Performance Evaluation of an Air-Based Solar Thermal Systemen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record